CHAPTER 7 PCI Card Hot Maintenance in SUSE Linux Enterprise Server 12
7.5 Hot add of IOU
-
Check if the I/O device is normally operating in the free partition. During addition, I/O pre-diagnostic
process is not executed.

7.5.2 DR operation of IOU hot add

This section describes the DR operation for IOU hot add.
1. Log into the MMB Web-UI using Administrator privileges.
2. Execute the hotadd command.
Example:When adding IOU1 in partition1.
Administrator > hotadd partition 1 IOU 1
Are you sure to continue adding IOU#1 to Partition#1? [Y/N]
Y
DR operation start (1/3)
Assigning IOU#1 to partition#1 (2/3)
Power on IOU#1 (3/3)
Adding IOU#1 to Partition#1 has been completed successfully.
Administrator >
3. See Operation Log window or perform "show dynamic_reconfiguration status" command and confirm
below messages.
Example: When adding IOU1 to partition 1.
Operation Log window:
"I_10110 Partition1 : Hot-add IOU#1 Completed."
show dynamic_reconfiguration status:
"Adding IOU#1 to Partition#1, completed"
4. Execute /opt/FJSVdr-util/sbin/dr stat IOU command in the operating system shell.
The list of IOUs connected to the system is displayed. Check if the IOU that was added is displayed.
Example: When IOU1 is added.
# /opt/FJSVdr-util/sbin/dr stat IOU
IOU0: online
IOU1: offline
IOU2: empty
IOU3: empty
When newly adding an IOU to a partition, it will be displayed as offline since the IOU is not recognized by
the operating system.
5. Execute /opt/FJSVdr-util/sbin/dr add IOU1 command in the operating system shell.
The IOU that was newly added to the partition will be powered on.
Example:When IOU1 is powered on
# /opt/FJSVdr-util/sbin/dr add IOU1
#
7.5.3 Operation after IOU hot add
This section describes the process and operation after IOU hot add.
Note
If SVAgent is installed in the partition, perform below command with root privilege.
# /usr/sbin/srvmagt restart
1. Check the resource that was added.
Execute the /opt/FJSVdr-util/sbin/dr show IOU command in the operating system shell.
Example:When IOU1 was added
# /opt/FJSVdr-util/sbin/dr show IOU1
0000:03:00.0 PCI bridge: PLX Technology, Inc. Device 8748
(rev ca)