Fujitsu PRIMEQUEST 2000 Series Administration Manual page 325

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

CHAPTER 8 Replacement of HDD/SSD
8.2 Preventive replacement of HDD/SSD with Hardware RAID configuration
[SBx] window of MMB Web-UI. For details on [SBx] window, see '1.2.13 [SB] menu' in "PRIMEQUEST
2000 series Tool Reference" (CA92344-0539).
-
For replacement of a HDD or SSD included in a DU
Confirm whether [Status] of replaced HDD or SSD has been already 'Operational' by [System] – [DU]
– [DUx] window of MMB Web-UI. For details on [SBx] window, see '1.2.15 [DU] menu' in
"PRIMEQUEST 2000 series Tool Reference" (CA92344-0539).
For non-mirror configuration (replacement with the partition power off)
If HDDs or SSDs are not mirror configuration, preventive replacement of a HDD or SSD has to be performed
with the partition power off
Remarks
-
If HDD or SSD other than target HDD or SSD for preventive replacement fails in step3, field engineers in
charge of your system replace the failed HDD or SSD.
-
Step7 is performed by the field engineer in charge of your system.
1. Back up data in all HDDs or SSDs connected to the RAID controller card to which the target HDD or SSD
for preventive replacement is connected.
2. Confirm the HDD or SSD which S.M.A.R.T. has predicted to fail by MMB Web-UI checking mounting
location. How to confirm the status differs depending on whether the HDD or SSD is included in an SB or
in a DU.
-
When S.M.A.R.T predicted to fail a HDD or SSD included in an SB
A HDD or SSD which S.M.A.R.T has predicted to fail is a HDD or SSD with its [status] 'SMART error'
in [System] – [SB] – [SBx] window of MMB Web-UI. For details on [SBx] window, see '1.2.13 [SB]
menu' in "PRIMEQUEST 2000 series Tool Reference" (CA92344-0539).
-
When S.M.A.R.T predicted to fail a HDD or SSD included in a DU
A HDD or SSD which S.M.A.R.T has predicted to fail is a HDD or SSD with its [status] 'SMART error'
in [System] – [DU] – [DUx] window of MMB Web-UI. For details on [DUx] window, see '1.2.13 [SB]
menu' in "PRIMEQUEST 2000 series Tool Reference" (CA92344-0539).
3. If HDD or SSD other than target HDD or SSD for preventive replacement fails, replace the failed HDD or
SSD prior to perform preventive replacement
4. Restart the partition.
In PRIMEQUEST 2400E3/2800E3/2800B3/2400E2/2800E2/2800B2, start HII Configuration Utility from
Boot Manager front page.
In PRIMEQUEST 2400E/2800E/2800B, Start WebBIOS from Boot Manager front page.
5. In PRIMEQUEST 2400E3/2800E3/2800B3/2400E2/2800E2/2800B2, perform Clear Confguration.
Selet [Clear Configuration] from [Configuration Utility] in [HII Configuration Utility].
Note
If you perform [Clear Configuration], all data are deleted.
In PRIMEQUEST 2400E/2800E/2800B, perform Clear Configuration or delete a VD.
-
For there is only one VD with RAID 0:
-
Select [Clear Configuration] from [Configuration Wizard] in [WebBIOS] and click [Next].
-
If below massage appears, click [Yes].
"This is Destructive Operation.
Original configuration and data will be lost.
Select Yes, if desired so."
Note
If you perform [Clear Configuration], all data are deleted. [Configuration Preview] window appears.
-
For the VD number of RAID 0 group is the most biggest among the environment where there are
multiple VDs:
Select the particular VD and delete it.
6. When the data has been erased, exit WebBIOS and power off the partition.
7. Replace the HDD or SSD which S.M.A.R.T. predicted to fail.
8. Start the partition.
In PRIMEQUEST 2400E3/2800E3/2800B3/2400E2/2800E2/2800B2, start HII Configuration Utility from
299
CA92344-0537-08

Advertisement

Table of Contents
loading

Table of Contents