CHAPTER 9 PCI Express card Hot Maintenance in Windows
9.4 FC Card Hot Plugging
-
In case of using SVAS or SVagent, "Source: SVAS or SVagent, ID: 25004 Error massage" is logged in
SEL when replacing, it is no problem.
9.4.1 Hot plugging an FC card incorporated with the ETERNUS
multipath driver
This section describes the hot plugging procedure for an FC card incorporated with the ETERNUS multipath
driver.
1. Make the necessary preparations.
Stop access to the faulty FC card, such as by stopping applications.
2. Enter Maintenance Mode in MMB Maintenance Wizard.
Administrater privilege is needed for this work. Log in MMB as Administrator.
a
Enter Maintenance Mode.
Start [Maintenance Wizard] menu in MMB Web-UI. [Maintenance Wizard] window appears. Select
[Enter Maintenance Mode] in Maintenance Type, and click [Next] button.
b
Select Maintenance Area.
Hot plug of PCI slot for Partition#0 is explained as example. Select [Partition], check Partition#0, and
click [Next] button.