8.3 Hot System Replacement

Disk unit
Power
Do not set the AC main line switch to OFF, nor disconnect the
CAUTION
power cable or RCI cable while the GP7000F main cabinet is
powered on, unless absolutely necessary. Otherwise, the data may
be destroyed in the disk units.
The SCA-II connector is used as the disk unit connector to enable hot system replacement of a
faulty disk unit. The availability is improved by combining this feature with the disk mirroring
feature. Two LEDs (ACTIVE and FAULT) are installed per disk unit to indicate the disk unit status.
These LEDs operate as described below.
Name
Color
ACTIVE LED
Green
FAULT LED
Amber
To hot-swap a disk unit, you need to use the software tool which is provided in "Basic Software
Extension" or "Enhanced Support Facility". Please refer to user's guide of "Basic Software
Extension" or "Enhanced Support Facility" for more information. The FAULT LED lights up
according to the procedures described in the user's guide to identify the failed disk unit. If the
FAULT LED does not light up even if you follows the procedures described in the user's manual,
hot-swapping is not possible. In this case, power-off the entire system, then replace the disk unit.
When adding a new disk unit while the system is running, use the software tool, as well.
When the power supply units are configured redundantly, it can be hot-swapped. Each power supply
unit has a POWER LED on it, and it lights steadily while the corresponding power supply is
working. When the POWER LED doesn't light, it indicates that the power is turned off or the power
unit has failed. Hot replacement of the power supply unit is possible only while the corresponding
POWER LED is off.
Use a software tool, which is provided in "Basic Software Extension" or "Enhanced Support
Facility", to how-swap a power supply unit. Please refer to user's guide of "Basic Software
Extension" or "Enhanced Support Facility" for more information.
Table 8.2
LEDs
Status
Lights up when the SCSI commands are executed.
Lights up when the hot replacement command is executed.
8.3 Hot System Replacement