CS9360 User's Guide
NOTE
Make sure that spectrophotometer is NOT installed at an angle, and that there in no gap
between the connector and spectrophotometer.
Step 10:
Press [Enter].
"Wait for a while..." is displayed.
The printer checks the connection between the printer and spectrophotometer.
"Set white plate then close left maintenance cover." is displayed.
Step 11:
Remove the white reference plate from the plate installation place, turn it over so that the
white side faces up, and install it back to the original place.
3
2
N°.
1
2
NOTE
Before measuring the color target, make sure that the white side of the white reference
plate is facing up.
If the black side is facing up, it will not be measured accurately.