Step 4:
Check the both ends and the centre of the print result that printed with Adjust pattern, and
select the number from 1 to 11 that is not out of alignment.
"3" is selected in the next printing sample of "Micro Adjustment Pattern A".
"5" is selected in the next printing sample of "Micro Adjustment Pattern B".
"4" is selected in the next printing sample of "Micro Adjustment Pattern F".
NOTE
"6" is the current setting value.
Step 5:
"PatternA: 6" is displayed.
3-61