This message is for the use case when an implementation has detected an Interconnect Configuration
Error.
May also be shown as 806f011b0701ffff or 0x806f011b0701ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0266
User Response
If the specified sensor is front USB connector, reset the front USB cable on the system board. If
the specified sensor is front video connector, reset the front video cable in the system board. If the
specified sensor is PwrPaddle cable, complete the following steps until problem is solved:
1. Reseat the power paddle cable on the system board.
2. Replace the power paddle cable.
3. (Trained technician only) Replace the supercap n. (n = supercap number)
4. (Trained technician only) Replace the system board.
Front Video :
806f011b-0c01ffff : The connector [PhysicalConnectorElementName] has encountered a
configuration error. (FP LCD Cable)
This message is for the use case when an implementation has detected an Interconnect Configuration
Error.
May also be shown as 806f011b0c01ffff or 0x806f011b0c01ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
SNMP Trap ID
50
Appendix A. Integrated management module II (IMM2) error messages