Lenovo x3650 M5 Installation And Service Manual page 745

Hide thumbs Also See for x3650 M5:
Table of Contents

Advertisement

SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0146
User Response
1. Make sure that the fans are operating, that there are no obstructions to the airflow, that the air
baffles are in place and correctly installed, and that the server cover is installed and completely
closed.
2. Make sure that ambient temperature is within the specifications.
3. If a fan has failed, complete the action for a fan failure.
4. Replace DIMM n. (n = DIMM number)
806f0a0c-200cffff : An Over-Temperature Condition has been detected on the
[PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 12)
This message is for the use case when an implementation has detected an Over Temperature Condition
for Memory that has been Detected.
May also be shown as 806f0a0c200cffff or 0x806f0a0c200cffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0146
User Response
1. Make sure that the fans are operating, that there are no obstructions to the airflow, that the air
baffles are in place and correctly installed, and that the server cover is installed and completely
closed.
2. Make sure that ambient temperature is within the specifications.
3. If a fan has failed, complete the action for a fan failure.
4. Replace DIMM n. (n = DIMM number)
806f0a0c-200dffff : An Over-Temperature Condition has been detected on the
[PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 13)
Appendix A. Integrated management module II (IMM2) error messages