Lenovo x3650 M5 Installation And Service Manual page 541

Hide thumbs Also See for x3650 M5:
Table of Contents

Advertisement

CIM Information
Prefix: PLAT ID: 0164
User Response
1. Run the hard disk drive diagnostic test on drive n.
2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling
the drive) b. Cable from the system board to the backplane
3. Replace the following components one at a time, in the order shown, restarting the server
each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk
drive backplane (n = hard disk drive number)
• 806f010f-2201ffff : The System [ComputerSystemElementName] encountered a firmware hang.
(Firmware Error)
This message is for the use case when an implementation has detected a System Firmware Hang.
May also be shown as 806f010f2201ffff or 0x806f010f2201ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Boot failure
SNMP Trap ID
25
CIM Information
Prefix: PLAT ID: 0186
User Response
1. Make sure the server meets the minimum configuration to start (see Power-supply LEDs).
2. Update the server firmware on the primary page. Important: Some cluster solutions require
specific code levels or coordinated code updates. If the device is part of a cluster solution, verify
that the latest level of code is supported for the cluster solution before you update the code.
3. (Trained technician only) Replace the system board.
806f0113-0301ffff : A bus timeout has occurred on system [ComputerSystemElementName].
(CPU 1 PECI)
This message is for the use case when an implementation has detected a Bus Timeout.
May also be shown as 806f01130301ffff or 0x806f01130301ffff
Appendix A. Integrated management module II (IMM2) error messages
529

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents