Lenovo x3650 M5 Installation And Service Manual page 195

Hide thumbs Also See for x3650 M5:
Table of Contents

Advertisement

Shipping bracket for
riser-card assembly
Figure 113. Riser-card assembly installation - full-height, full-length adapters
Step 6.
Replace the top cover (see "Replacing the top cover" on page 144).
Step 7.
Slide the server into the rack.
Step 8.
Reconnect the power cords and any cables that you removed.
Step 9.
Turn on the peripheral devices and the server.
Removing the dedicated slotless RAID controller
Use this information to remove the dedicated slotless RAID controller.
The dedicated slotless RAID controller can be installed in the dedicated connector on the system board (see
"System-board internal connectors" on page 28 for the location of the connectors).
To remove the dedicated slotless RAID controller, complete the following steps:
Step 1.
Read the safety information that begins on "Safety" on page v and "Installation guidelines" on
page 289.
Step 2.
Turn off the server and peripheral devices and disconnect the power cords and all external cables,
if necessary.
Step 3.
Remove the top cover (see "Removing the top cover" on page 143).
Step 4.
Disconnect the signal cables from the connectors on the controller and note their locations.
Step 5.
1
Press the retention tabs away from the controller; then, slightly lift up the rear of the controller,
and
2
pull it out of the connector on the system board.
PCI riser-card
assembly 2
PCI riser-card
assembly 1
.
Chapter 5
Removing and replacing components
183

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents