Lenovo x3650 M5 Installation And Service Manual page 108

Hide thumbs Also See for x3650 M5:
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
• Go to the support website at http://www.lenovo.com/support to check for technical information, hints, tips,
and new device drivers or to submit a request for information.
Symptom
The Pwr rail H error has been
recorded in the system event
log.
The Pwr rail I error has been
recorded in the system event
log.
96
Lenovo System x3650 M5 Installation and Service Guide
Action
6. (Trained technician only) replace the system board (see "Removing the system
board" on page 283 and "Replacing the system board" on page 286).
7. Reinstall the Microprocessor 1; then, restarting the server. If the Pwr rail G error
has been recorded in the system event log again, the Processor that you just
reinstalled is defective. Replace the defective Processor.
• (Trained technician only) Microprocessor 1 (See "Removing a microprocessor
and heat sink" on page 267 and "Replacing a microprocessor and heat sink"
on page 273).
1. Disconnect the server power cords.
2. Remove the following components if the Pwr rail H error has been recorded in
the system event log:
• Hard disk drives at backplane assembly 3
• Hard disk drive backplane assembly 3
• PCIe Solid state drives
• PCIe Solid state drive backplane assembly
3. Restart the server. If the Pwr rail H error has been recorded in the system event
log again, (trained technician only) replace the system board (see "Removing the
system board" on page 283 and "Replacing the system board" on page 286).
4. Reinstall the components one at a time, in the order shown, restarting the
server each time. If the Pwr rail H error has been recorded in the system event
log again, the component that you just reinstalled is defective. Replace the
defective component.
• Hard disk drive backplane assembly 3
• Hard disk drives at backplane assembly 3
• PCIe Solid state drive backplane assembly
• PCIe Solid state drives
1. Disconnect the server power cords.
2. Remove the following components if the Pwr rail I error has been recorded in
the system event log:
• Hard disk drives at backplane assembly 1 and/or backplane assembly 2
• Hard disk drive backplane assembly 1 and/or backplane assembly 2
3. Restart the server. If the Pwr rail I error has been recorded in the system event
log again, (trained technician only) replace the system board (see "Removing the
system board" on page 283 and "Replacing the system board" on page 286).
4. Reinstall the components one at a time, in the order shown, restarting the
server each time. If the Pwr rail I error has been recorded in the system event
log again, the component that you just reinstalled is defective. Replace the
defective component.
• Hard disk drive backplane assembly 1 and/or backplane assembly 2
• Hard disk drives at backplane assembly 1 and/or backplane assembly 2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents