Lenovo x3650 M5 Installation And Service Manual page 198

Hide thumbs Also See for x3650 M5:
Table of Contents

Advertisement

Slot 1
Slot 2
Slot 3
Figure 117. PCI riser-card adapter expansion slot locations
2.5-inch rear two
hard-disk-drive kit
Slot 3
Figure 118. PCI riser-card adapter expansion slot locations
The following table describes the maximal card dimension supported in each slot.
Table 14. The maximal card dimension supported in each slot
Riser-card assembly
Riser-card assembly 1
Riser-card assembly 2
Note: If you are replacing a high power graphics adapter, you might need to disconnect the internal power
cable from the system board before removing the adapter.
To remove an adapter, complete the following steps:
Step 1.
Read the safety information that begins on "Safety" on page v and "Installation guidelines" on
page 289.
Step 2.
Turn off the server and peripheral devices and disconnect all power cords; then, remove the top
cover (see "Removing the top cover" on page 143).
Step 3.
Press down on the left and right side latches and slide the server out of the rack enclosure until
both slide rails lock; then, remove the top cover (see "Removing the top cover" on page 143).
Step 4.
Remove the riser-card assembly that contains the adapter (see "Removing a riser-card assembly"
on page 179).
• If you are removing an adapter from PCI expansion slot 1, 2, or 3, remove riser-card assembly 1.
186
Lenovo System x3650 M5 Installation and Service Guide
3.5-inch rear two
Slot 4
Slot 5
hard-disk-drive kit
3.5-inch rear two
Slot 4
Slot 5
hard-disk-drive kit
Slot
number
The maximal card dimension supported
1
Full height, up to full length
2
Full height, up to full length
3
Full height, half length
4
Low-profile
5
Low-profile
6
Full height, up to full length
7
Full height, up to full length
8
Full height, half length