Step 9.
If you removed the fan cage, install it. (See "Replacing the fan cage assembly" on page 172).
Step 10. Insert the hard disk drives and the fillers the rest of the way into the bays.
Installing a 8x 2.5-inch hot-swap HDD assembly with expander kit
Use this information to install a 8x 2.5-inch hot-swap HDD assembly kit with expander.
You can install a Lenovo System x3650 M5 8x 2.5-inch hot-swap HDD assembly with expander kit to
add eight additional 2.5-inch hot-swap hard disk drives in the server. See http://www.lenovo.com/us/en/
serverproven/ for a list of supported optional devices. To order a 8x 2.5-inch hot-swap HDD assembly kit
with expander, contact your sales representative or reseller.
The 8x 2.5-inch hot-swap HDD assembly with expander kit contains the following components:
• Eight 2.5-inch HDD fillers
• One expander
• Two power/configuration cables (230 mm)
• One power/configuration cable (260 mm)
• One mini-SAS HD Y-cable (580/590 mm)
• One mini-SAS HD cable (350 mm)
• One mini-SAS HD cable (150 mm)
• Two mini-SAS HD cables (250 mm)
Note: The 8x 2.5-inch hot-swap HDD assembly with expander kit including structural parts and Tier 1 parts.
To install a 8x 2.5-inch hot-swap HDD assembly with expander kit, complete the following steps:
Step 1.
Read the safety information that begins on "Safety" on page v and "Installation guidelines" on
page 289.
Step 2.
Turn off the server and peripheral devices and disconnect the power cords and all external cables,
if necessary.
Step 3.
Remove the top cover (see "Removing the top cover" on page 143).
Step 4.
Remove the two 4-drive filler panels.
4-drive filler panel
Figure 271. Filler panels
Step 5.
To obtain more working room, remove the fan cage (see "Removing the fan cage assembly" on
page 171).