Prefix: PLAT ID: 0498
User Response
1. Check operator informationpanel cable is connected.
2. Check the ambient temperature. You must be operating within the specifications (see Server
Features and specifications for more information).
3. Replace operator information cable or usb assembly cable.
4. (Trained technician only) Replace system board.
• 80030006-2101ffff : Sensor [SensorElementName] has deasserted. (Sig Verify Fail)
This message is for the use case when an implementation has detected a Sensor has deasserted.
May also be shown as 800300062101ffff or 0x800300062101ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0509
User Response
No action; information only.
• 80030012-2301ffff : Sensor [SensorElementName] has deasserted. (OS RealTime Mod)
This message is for the use case when an implementation has detected a Sensor has deasserted.
May also be shown as 800300122301ffff or 0x800300122301ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
Appendix A. Integrated management module II (IMM2) error messages
423