FUEL SYSTEM
7-8
2. Check the fuel quick connect fitting (1) for dirt, and
clean if necessary.
Place a shop towel [2] over the quick connect fitting .
3. Pull and release the connector damper [1) from the
retainer.
4. Hold the connector [2] with one hand and squeeze
the retainer [3J tabs with the other hand to release
Ihem from the locking pawls [4] .
If using the special tool:
Pull and release the connector damper II I from the
retainer as shown.
Set the special 1001 to the
retainer
tabs and push and
release them from the locking pawls.
(5J Fuel connector remover
070MF· HP50200
Pull the connector off, then remove the relainer and
connector damper from the
pipe
end.
NOTE:
Absorb the remaining fuel in the fuel feed hose from
Howing out with a shop towel.
Be careful not to damage the hose or other parts.
Use the specified special tool only.
If the connector does not move , keep the retainer
tabs pressed down , and alternately pull and push
the connector until it comes off easily.
5. To prevent damage and keep foreign matter oul.
cover the disconnected connector and pipe end with
the plastic bags [1].
15J
(1J
(31
III