Ch.5 Web Maintenance Mode
5-3-5 PRINT CONDITION <PRINT SETUP>
Allows to assign a default print condition to each diagnostic device for the case that the
print condition is not designated by the diagnostic device.
Item
Default
LUT SELECT
1
DENSITY
0
CONTRAST
0
SMOOTH
2
DENSITY MAX CH1, 2 : 300
Ch3 : 400
CH4 - : 300
DENSITY MIN
20
ILLUMINATION
2000
AMBIENT
10
LIGHT
FLIP
OFF
DRYPRO Vstage MODEL 793 Operation Manual Ver.1.01 2005.1
Descriptions
Select the LUT for the print condition.
Select from "1" - "7".
Use "LUT Setup" of the Maintenance Mode to set the details of LUT.
Sets the density of the image. Select from "-7" - "+7". More negative, lighter the density,
more plus, darker.
Sets the contrast (contrast between light and dark of the image) of the image.Select from "-7"
- "+7". More negative, lower the contrast, more plus, higher.
Sets the smoothing of the image. Select from "0"~"7".
In the range of "0"~"6", larger the value, smoother the image. However, too large in value
makes the image blur.
Selecting "7" gives the same smoothing result as "0" is selected. The image will be printed in
one to one scale.
Recommended is"2" or "3".
Sets the max. density of the printed image. Set between "150" ~ "400".
Higher the value, higher the max. density. Lower the value, lower the
max. density.
Sets the min. density of the printed image. Set between "10" ~ "30". Higher the value, higher
the min. density. Lower the value, lower the min. density.
Sets the luminance of the light table. Normally, this value is specified and sent from the diag-
nostic device. Set between "0" ~ "38000".
Sets the ambient light. Normally, this value is specified and sent from the diagnostic device.
Set between "0" ~ "38000".
Selects whether to flip the print image. Select from OFF (not reversed) or ON (reversed).
Selecting "ON(reversed)" will print the image laterally reversed.
< 111 >