Peripheral Link (P-LINK) Side LEDs

© Polycom, Inc.
E1 PRI Network Interface Module
Solid yellow LED
Blinking yellow LED
Solid red LED and solid yellow
LED
Solid green LED
The P-LINK side of the PRI network interface module has two
vertical LEDs: green and amber. The various LEDs indicate the
following:
Solid amber LED
The PRI network interface
module is receiving clock and
frame sync, and receiving
Remote Alarm Indication (RAI)
from the network without any
Cyclic Redundancy Check
(CRC) errors.
The PRI network interface
module is receiving clock and
frame sync, and receiving RAI
from the network with CRC
errors.
The PRI network interface
module is receiving clock sync,
and receiving AIS Alarm
Indication Signal (unframed
all-ones).
The ViewStation FX or VS4000
is fully synchronized with the
network and is ready to use.
The PRI network interface
module is in boot mode. If the
stays lit for more than a minute,
new microcode is being
uploaded from the ViewStation
FX or VS4000 to DRAM.
189