Code
Description
0000 The reading of the main thermistor is not 100 deg C 12 sec after it has
exceeded 70 deg C.
0001 The reading of the main thermistor is not 150 deg C 15 sec after it has
exceeded 100 deg C.
0010 The power has been turned off and then back on without resetting the error. - Reset the error. (COPIER>FUNCTION>CLEAR>ERR)
E003
There is an abnormal rise in temperature.
After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
0000 The reading of the main thermistor is lower than 70 deg C for 2 sec or more
after it has exceeded 100 deg C.
0010 The power has been turned off and then back on without resetting the error. - Reset the error. (COPIER>FUNCTION>CLEAR>ERR)
E004
The IH power supply is faulty/the IH control mechanism is faulty.
After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
0010 The power has been turned off and then back on without resetting the error. - Reset the error. (COPIER>FUNCTION>CLEAR>ERR)
0101 There is a mismatch between the input voltage and the IH power supply ID. Replace the fixing heater power supply with one designed for the country
0102 The IH current is faulty. (current leakage)
0103 The IH current is faulty. (no current)
0104 There is an IH over-current.
0105 The IH input voltage is too high.
0106 The IH input voltage is too low.
0201 At power-on (or, when IH is at reset), the IH control mechanism is not in
an initial state.
0202 At IH start-up, the IH control enable flag is not set within 1 sec after the
start flag is set.
0203 With IH at rest, the IH control flag is not released.
0204 The 12-V power supply (IH relay) is identified as being off.
0205 At IH start-up, the PWM/ON data is faulty ('0' or 'FFFF')
E005
There is no fixing web/there is an error in the detection of web solenoid connection.
0000 The absence of the fixing web has been detected for 5 sec or more.
0001 At power-on, the connection of the web solenoid is not detected.
0010 The power has been turned off and then back on without resetting the error. - Reset the fixing web counter. (COPIER>COUNTER>MISC>FIX-WEB)
E010
There is a feed motor error.
0000 The FG signal of the feed motor does not arrive for 2 sec or more even
when the feed motor has been turned on.
E012
There is a drum motor error.
0000 The FG signal of the drum motor does snot arrive for 2 sec or more even
when the drum motor has been turned on.
Remedy
- Check the connector of the main/shutter thermistor for any fault in
connection and wiring.
- Check the main/shutter thermistor for mounting condition.
- Replace the main/shutter thermistor.
- Replace the fixing heater unit.
- Replace the DC controller PCB.
- Check the connector of the main/shutter thermistor for any fault in
connection and wiring.
- Check the main/shutter thermistor for mounting condition.
- Replace the main/shutter thermistor.
- Replace the fixing heater unit.
- Replace the DC controller PCB.
of installation (voltage).
- Check the connector for any fault in connection.
- Replace the fixing heater power supply.
- Replace the DC controller PCB.
- Replace the DC controller PCB.
- Replace the fixing web.
- Replace the fixing web length sensor.
- Replace the DC controller PCB.
After correcting the fault, be sure to reset the fixing web counter reading.
(COPIER>COUNTER>MISC>FIX-WEB)
- Check the connector for any fault in connection.
- Replace the solenoid.
- Check the connector for any fault in connection.
- Replace the motor
- Check the connector for any fault in connection.
- Replace the motor.