Tait TM9100 Service Manual page 341

Hide thumbs Also See for TM9100:
Table of Contents

Advertisement

If neither the voltage nor the current measured in
Task 15 —
Shaping Filter for
the shaping filter for the power-control circuitry or the CODEC and audio
Power Control
circuitry is suspect.
Important
1.
2.
3.
4.
5.
6.
TM9100 Service Manual
© Tait Electronics Limited August 2005
Ensure that the current limit on the DC supply is 2A.
And, when entering the CCTM command 331 x, do not
specify a value x higher than that recorded in
Failure to do so might result in the destruction of the PAs.
Use the multimeter to measure the voltage at the
(see
Figure
12.9). The voltage should be:
FIN1 test point: 18 ± 2mV (initially)
Enter the CCTM command 331 x (where x was recorded in
Check that the voltage changes to:
FIN1 test point: 1.1 to 2.7V (after entry of CCTM 331 x)
Enter the CCTM command 32 to place the radio in receive mode.
If the voltage measured above is correct, go to
to
"CODEC and Audio Fault Finding" on page
Check IC301 and the surrounding shaping-filter circuitry
(see
Figure
12.9). If a fault is found, repair it, confirm the removal
of the fault, and go to
"Final Tasks" on page
replace the main-board assembly and go to
page
147.
Transmitter Fault Finding (25W Radios)
Task 13
is correct, then
Task
12.
1 test point
FIN
Task
12).
Step
6. If it is not, go
371.
147. If the repair failed,
"Final Tasks" on
341

Advertisement

Table of Contents
loading

Table of Contents