Rx If (J13); Rx L-Band If (J14); Alarm (J15); Ext Clk (J16) - Comtech EF Data DMD50 Installation And Operation Manual

Universal satellite
Table of Contents

Advertisement

DMD50 Universal Satellite Modem

5.4.4 RX IF (J13)

The Receive IF Input Port is a 75-Ohm Female BNC Connector that is used for 70/140 MHz IF.
If the customer orders the 70/140 MHz IF, the Transmit IF Output Port is a 75-Ohm Female BNC
Connector.

5.4.5 RX L-Band IF (J14)

The Receive IF Input Port is a 50-Ohm SMA Female Connector that can be used for L-Band IF.
The IF Frequency can be programmed from 950 to 2050 MHz in 1 Hz Steps.

5.4.6 ALARM (J15)

The Alarm Port is a 15-Pin Female "D" Connector. Refer to Table 5-2 for pinouts.
Pin No.
1
Mod Fault - C
2
Mod Fault – NC
3
Mod Fault – NO
4
Demod Fault - C
5
Demod Fault – NC
6
Demod Fault – NO
7
Prompt - C
8
Prompt – NC
9
Prompt – NO
10
Service – C
11
Service – NC
12
Service – NO
13
No Connection
14
AGC Out
15
Ground

5.4.7 EXT CLK (J16)

The External Clock Port is a 75-Ohm Female BNC Connector. It allows interfacing to an
external clock source.
Input level: .3 to 5 volts Peak-to-Peak. (Sine or Square wave)
MN-DMD50– Revision 3
Table 5-2. ALARM Port 15-Pin Female "D" Connector (J15)
Signal Name
Signal
Direction
MF-C
No Direction
MF-NC
No Direction
MF-NO
No Direction
DF-C
No Direction
DF-NC
No Direction
DF-NO
No Direction
CEF-C
No Direction
CEF-NC
No Direction
CEF-NO
No Direction
SP1-NO
No Direction
SP1-NC
No Direction
SP2-NO
No Direction
SP2-NC
No Direction
AGC
No Direction
GND
User Interfaces
---