ELECTRICAL SYSTEM
• Securing the voltage regulator ground cable (9) (TE - TXC)
Secure the regulator ground cable to the right-hand screw of the injection coil.

• Securing the engine ground / chassis ground cables (10).

Electrical system ground

Secure the engine ground / chassis ground cable and the wiring harness ground
eye terminal to the coil retaining screw.

• Wiring connection to voltage regulator (TE - TXC)

Connect the connector (11) to the regulator. Pay attention to the routing of radia-
tor breather hose and throttle cables.