Voltage regulator-rectifier checking (TE-SMR-TXC)
With the ignition definitely functional, whilst the battery is charged (12.5V-13V),
start the engine: if the battery tension does not increase (14 V) after about two
minutes, substitute the regulator. To access the regulator, remove the seat and
fuel tank (pages E.15, E.23). Remove the fixing screw (1) and the regulator.
For the key to electrical cables and
components, see pages M.4÷M.5.
Part. N. 8000 H0368 (09-2008)
ELECTRIC SYSTEM, DIGITAL INSTRUMENT