Honeywell GX-Series Installation And Setup Manual page 68

Gx series;
Table of Contents

Advertisement

GX-Series Control Panel Installation and Setup Guide
If no modules have been added or removed, "NO MODULES ADDED, ESC TO CONTINUE" is
displayed. Pressing esc returns the system to the normal banner.
If modules have been removed they are reported as missing; the engineer is prompted to view the
missing modules and to remove them from the system by pressing the *; a warning is given before
the module is removed. Press the ent key to confirm the removal of the module. Once all missing
modules are removed, the GX-Series reports the previous and current number of modules connected
to the system, before returning to the normal banner.
If modules have been added, the GX-Series reports the previous and current number of modules
connected to the system, before returning to the normal banner.
If the esc key is pressed at any time during the exit engineer mode procedure, the procedure is aborted and
the GX-Series returns to the engineer mode. This return may take several seconds to complete.
Manager Code
The manager is authorized to modify the manager PIN — the manager PIN cannot be deleted — and assign
the access features to the code.
If authorized via menu option 48.2 the manager is also authorized to:
program the User Code options of each of the user codes;
allocate other codes to the manager type (3.6);
NOTE: The manager PIN can be reset to the default code (12345) by the engineer and remote code using the
Reset Mgr (Manager) parameter (refer to option 51.21).
The manager code defaults to group choice when groups are enabled. The manager is able to toggle the
group choice option on and off (using the * key) as required. The manager code defaults to accessing the full
menu (options 11 – 48). To access the quick menu (options 0 – 9), remove the * assigned to the manager in
the Modify Level option.
Programming Codes
Each PIN user has access to modify their own PIN. Users do not have access to user codes other than their
own. The only exception to this is the manager code.
42.1 = User Codes
Enter option 42=Codes and select option 1=User Codes. Press the ent key; details of the first user (User
001) are displayed. The following typical information is displayed on the keypad.
Each of the users can be displayed using the A> and <B keys, or a specific user can be selected by entering
the required user number (e.g., 023, 069). When the required code is displayed, press the ent key to select
the user codes modification options; 1=Modify PIN is displayed. The available modification options can be
viewed by pressing the A> or <B keys; press the ent key to select the required option. The options are
detailed in the following paragraphs:
USER NUMBER
1 U s e r
L2.3
USER TYPE
= NO PIN ASSIGNED
= PIN ASSIGNED
USER
NAME
ACCESS CONTROL
CARD ASSIGNED
m
A
1 2 3 4
GROUP MODE
6-22