GX-Series Control Panel Installation and Setup Guide
03 Intruder
The Intruder function is inactive when the system is unset (disarmed). When the system is set (armed),
activation of an Intruder zone causes a full alarm activation that requires to be reset with a code
authorized for System Reset – refer to option 51.6 = PARAMETERS.System Reset and option 51.55.3 =
PARAMETERS.Confirm.Reduce Reset.
All zones are programmed as Intruder by default; this includes the zones on RIOs that are added to the
system at a later date.
04 24 Hours
The 24 Hours zone function is continuously operational. In the unset (disarmed) state, activation of the zone
function generates a local alarm condition (the Intruder outputs are not activated). If the zone is activated
while the system is set, the 24 Hours function operates the same as an Intruder function and results in a
full alarm condition. The 24 Hours zone function requires a system reset following an activation in both the
set (armed) and unset (disarmed) conditions.
05 Security
The operation of the Security zone function is identical to the 24 Hours zone function, except a Security
zone activation in the unset (disarmed) state generates a local alarm (Horn outputs activated) that does not
require a system reset; any valid code (type 2 or above) cancels the alarm and resets the system. An
activation in the set (armed) state generates a full alarm that requires a system reset. The activation (+) and
restoration (–) of Security zones is recorded in the event log.
06 Dual (Double Knock) {Not for UL installations}
The operation of the Dual (Double Knock) function is identical to the Intruder function, with the exception
that an alarm condition is activated only when there have been two activations from any Dual zones
(assigned to the same group) within a 20 minute period while the system is set.
07 Entry
This function initiates the unsetting (disarming) procedure in the same way as a Final zone. However,
during the setting (arming) routine an Entry zone operates as an Exit zone type. This function is normally
used in conjunction with a Push Set zone, which acts as the exit terminator for the setting (arming)
procedure.
Pressing the * key when programming an Entry zone doubles the entry time of the group.
Opening an Entry zone during the exit time is reported on the keypad as an open zone; the Entry/Exit
Horns bleep rapidly to indicate that the zone is open.
08 Push Set {Not for UL installations}
This zone function is used to terminate the setting (arming) routine. The system sets when the Push Set
zone, usually a push button, is activated. The Entry/Exit Horn stops immediately the button is pressed;
the system sets after four seconds, allowing the doors to settle to the closed state. The Push Set zone
remains inactive until the next setting (arming) routine.
NOTE: The Push Set zone can be either 1kΩ going to 2kΩ or 2kΩ to 1kΩ - refer to Installation Manual (II1-
0033), System Architecture for wiring details. The first time that the Push Set is used to terminate the
setting/arming, the button will require to be pressed twice; the first press identifies the normal status of
the button to the system.
Activating a Push Set zone during the exit time is not reported on the keypad as an open zone; the Entry/
Exit Horns bleep rapidly to indicate that the zone is open.
NOTE: The termination feature of a Final zone can be extended to terminate the setting (arming) of multiple
groups by pressing the * key when assigning a group to the zone. Refer to the Star * Group Function.
6-58