Option 46 – Group omit (Area bypass)
This option allows a 3.6 type code to block omit all the omittable zones that are open at the end of the
confirm time in a group or multiple groups. All zones in the required groups that have the omit attribute
enabled (refer to option 52.4 = PROGRAM ZONES.Omit) are omitted (bypassed) when this option is
selected. Groups can be omitted and reinstated without setting (arming) and unsetting (disarming) the
system.
On selecting the Group omit (Area bypass) Option the groups assigned to the user code and keypad are
displayed as well as the omit status of each group (Y below the group indicates that it is omitted, N indicates
that it is not omitted). To omit a group, press the required key. The letter beneath the group number
changes from N to Y. To reinstate the group, press the key to toggle from Y to N.
NOTE: 1. The type 3.6 user must have group choice to enter Group omit (Area bypass).
2. The zones in the selected groups are omitted from the system as soon as the group is selected.
On returning to the banner (normal or engineer) the keypad displays the message ZONES OMITTED.
Omitted zones remain omitted for one set (armed) period only or until they are manually reinstated to the
system.
Outputs programmed as Zone Omit (mode programmed as reflex (follow) are activated as soon as the zone
is omitted and remains active until the zone is reinstated. If the output mode is programmed as latch, then
the Zone Omit outputs activate when the system is set (armed) and remain active until the system is unset
(disarmed) — reinstating the omitted zones.