GX-Series Control Panel Installation and Setup Guide
2 = Status
The Status attribute determines the system conditions that custom zone is operational in. The four
Status attributes are:
1. Unset activates an alarm when the system is unset (disarmed),
2. Entry/Exit activates an alarm when the system is setting (arming) and unsetting (disarming),
3. Part Set activates an alarm when the system is part set (part armed),
4. Full Set activates an alarm when the system is full set (full armed).
The default for each of the Status attributes is disabled. To enable the zone to activate an alarm, select
the required Status attribute using the A> or <B keys and press the # key; the display indicates that a
custom zone activation while the system is in the selected Status will create an Alarm condition and
switch on the assigned outputs.
NOTE: The custom zone can be operational in all four Status conditions if required.
3 = Setting
The Setting attribute determines the function (if any) that the custom zone has in setting (arming) and
unsetting (disarming) the system.
1. Begin Set if enabled, the custom zone starts the setting/arming setting (arming) procedure,
2. Begin Entry if enabled, the custom zone starts the unsetting (disarming) procedure,
3. Sets System if enabled, the custom terminates the setting (arming) procedure.
The default for each of the Setting attributes is disabled. To enable the options, select the required
Setting attribute using the A> or <B keys and press the # key; the display indicates that attribute
is ENABLED for the custom zone.
NOTE: The custom zone can be assigned all three Setting attributes if required, however, it is
recommended that either attribute 1 (Begin Set) or 3 (Sets System) is enabled, but not both.
4 = Log
This attribute determines which custom zone activations are logged. On selecting Log the current
selection is displayed. To change the selection press the # key, this toggles between the Log options;
Disabled the custom zone activations are not logged,
Entry/Exit the custom zone activations only log during the setting (arming) and unsetting
(disarming) procedure,
24 Hours all custom zone activations log [both in the set (armed) and unset (disarmed) states]
Alarms the custom zone only logs when an activation results in an alarm condition.
NOTE: The opening (+) and closing (–) of custom zones are recorded in the event log.
Assemble Zone Example:
Assemble a zone that:
activates Bells outputs when the system is set (armed),
activates Link-A outputs when the system is unset (disarmed),
generates an alarm condition when the system is part and full set,
does not generate an alarm condition during the setting (arming) and unsetting (disarming)
procedure,
acts as a terminator when the system is setting (arming),
logs all activation [in both set (armed) and unset (disarmed) states].
Programming:
(Assuming factory default settings)
1. Select option 64 = ASSEMBLE ZONES; press the ent key,
2. Select custom zone (1 = Custom-A, 2 = Custom-B); press the ent key,
3. Outputs is displayed. Press the ent key to select this option,
4. Bells is displayed. Press the # key. Set is displayed,
5. Enter 51. Link-A is displayed. Press the # key. Set is displayed,
6. Press the # key. Unset is displayed,
6-118