GX-Series Control Panel Installation and Setup Guide
Operating a keyswitch zone type during the pre-warn period of an autoset will start a Force Set. If you then
activate the switch again (i.e. unset (disarmed) with keyswitch) before the panel sets, the pre-warn
continues on the autoset.
NOTE: When the keyswitch is activated the second time to take panel back into pre-warn, it can be up to10
seconds before the pre-warn tones at the keypad start up again.
Lockout
Each group can be allocated with up to 67 (dependent on panel variant) Lockout schedules over a seven day
period. These can be combined in any order of On and Off times as required.
If Lockout has been assigned to a group, the group is locked-out at the Lockout On time or when the
group sets - whichever occurs first. Outputs programmed as Lockout are active while the system is locked
out – this will not always correspond to the times assigned to the Lockout depending on whether the group
sets prior to Lockout On. When a group is locked-out the setting (arming) status indicates that it cannot be
unset (disarmed) by displaying and L.
During the Lockout period, the group can not be unset (disarmed) unless an alarm has been activated in
the group. In the event of an alarm occurring during the Lockout period, any valid type 2.3 (or above) code
assigned to the group in alarm may be used to unset (disarm) and/or reset the group. If multiple locked-out
groups are in an alarm condition entry of a single valid code (type 2.3 or above with access to the relevant
groups) cancels the alarms and unsets (disarms) the activated groups.
The group can only be manually unset (disarmed) once in each Lockout Off period. If no Lockout times are
programmed, the group may be unset (disarmed) at any time.
Codes are not affected by Lockout, and can be used to gain access to the menus and to manually set (armed)
the group.
Programming Lockout
There are two stages to programming the Lockout function. These are options 6 = Lockout Status and
7 = Lockout Schedule of the Autoset programming menu:
6 = Lockout Status
The lockout status has to be set to On before the lockout schedule will function.
0 = Off (default)
1 = On
7 = Lockout Schedule
This option allocates the automatic lockout time schedule OFF (Unlock) and On (Lockout) for the selected
group. Up to 67 weekly schedules are available which are programmed in 65.1=Weekly Schedule.
1 2 3 4 5 6 7 8
r o u p s
L L L U U L L S
GX-089-V0
6-124