GX-Series Control Panel Installation and Setup Guide
Pressing the * key when programming a Part Final zone doubles the entry time of the group.
Opening a Part Final zone during the exit time is reported on the keypad as an open zone; the Entry/Exit
Horns bleep rapidly to indicate that the zone is open.
12 Part Entry
This zone has dual functionality depending on whether the system is full set (full armed) or part set (part
armed). When the system is full set the zone operation is identical to the Exit zone function. When the
system is part set the zone operation is identical to the Entry zone function.
Pressing the * key when programming a Part Entry zone doubles the entry time of the group.
13 PA
The PA (Personal Attack) function is continuously operational. Activation of this zone type overrides the
Bell Delay parameter and causes an instant full alarm condition that requires to be reset with a code
authorized for PA Reset — refer to Option 51 – PARAMETERS, 22 = PA Reset; the Intruder outputs
are not activated by PA zones.
NOTE: If a PA zone is open, it is indicated on the keypad whenever a valid code is entered. The group that the
open PA is assigned to cannot be set (armed) until it is closed.
14 PA Silent
The PA Silent function is identical to the PA function, with the exception that there is no audible or visual
indication of the activation; that is, no bells or strobes are activated. Only the PA output (normally channel
2 on the digital communicator) signals the alarm. The activation (+) and restoral (–) of PA Silent zones is
recorded in the event log.
NOTES
1. At the time of setting (arming), any PA Silent zones that are currently open are reported to the user.
2. The tamper facility on the PA zone remains active while engineer mode is accessed.
3. Engineer mode cannot be exited if a PA Silent zone is open.
15 PA Delay
The PA Delay function is identical to the PA function, with the exception that the PA output activation can
be delayed for up to 60 seconds; this is determined by option 51.13 = PARAMETER.PA Delay. During the
period of delay the Entry/Exit Horns activate to remind the user that the PA delay is counting down;
entering a valid code or closing the PA Delay zone aborts the alarm.
NOTES
1. If a PA Delay zone is open, it is indicated on the keypad whenever a valid code is entered. The
group that the open PA Delay is assigned to cannot be set (armed) until it is closed.
2. The tamper facility on the PA zone remains active while engineer mode is accessed.
16 PA Delay Silent
The PA Delay Silent function is identical to the PA Delay function, with the exception that there is no
audible or visual indication of the activation; that is, no bells or strobes are activated. Only the PA output
(normally channel 2 on the digital communicator) signals the alarm. The activation (+) and restoral (–) of PA
Delay Silent zones are recorded in the event log.
NOTES
1. At the time of setting (arming), any PA Delay Silent zones that are currently open are reported to
the user.
2. The tamper facility on the PA zone remains active while engineer mode is accessed.
17 Link
This zone type has no operational function; it is designed to be used as a source of a link - refer to option 54
= LINKS. The activation (+) and de-activation (–) of Link zones is recorded in the event log.
18 Spare
The Spare function allows any zones that are not being used to be ignored by the system; the resistance
readings from the circuit - including the tamper conditions - do not activate an alarm condition.
NOTE: It is recommended that all unused zones are programmed as Spare and that a 1kΩ 1% resistor is
connected across each of these zones.