GX-Series Control Panel Installation and Setup Guide
47.1 Service
This option enables type 3.6 users to control the access mode of the remote servicing package. There are
several options available for increased flexibility and security.
0 = INT Telecoms
This option selects the on-board telecoms as the communication device.
0 = Direct Access
On selecting this option, a 40 minute access period is enabled on the GX-Series panel; remote
servicing software can directly access the system during this period. Once access to the panel has
been gained, it can be maintained indefinitely; there is no maximum duration. On terminating the
remote servicing connection to the panel, the access period remains valid for an additional 15
minutes.
1 – 5 = Call Back 1 – 5
A maximum of five numbers can be preprogrammed by the engineer (refer to option 56.1.12 =
COMMUNICATIONS.Telecom.Remote Access). On selecting one of the numbers (1 – 5) followed
by the ent key, the GX-Series panel dials out to the preprogrammed telephone number associated
with the Call Back number.
If the number selected does not have a preprogrammed telephone number, the system prompts for a
number 1 to be entered. Enter the required telephone number and press the ent key; the panel then
dials out to the telephone number entered.
NOTE: The PC that the panel is dialing to must have remote servicing software running in the Waiting
for Call-Back mode.
1 = NOT USED
2 = Ethernet
0 = Direct Access
See INT Telecoms description.
1 – 5 = Call Back 1 – 5
See INT Telecoms description (except menu option 56.4.03 replaces 56.1.12).
3 = NOT USED
47.2 Send Alarms
Option not available
47.3 Call GX-Series
Option not available
47.4 Auto Service
The GX-Series panels can be programmed to automatically initiate communications to remote servicing
software, under three circumstances:
If any site programming has changed the panel will automatically send the new programming to the
downloader.
On a predetermined schedule the panel can activate an automatic periodic upload.
On a predetermined schedule the panel can activate an automatic remote routine inspection.
NOTE: The Auto Service function works for both the Internal Telecoms and Ethernet module.
The following sub options allow the engineer to select the mode of the automatic communication in each of
the three situations. These options are not available to users.
1 = Mode
This selects the mode of the automated connection following a change to the panel programming. There are
four modes:
6-34