Honeywell GX-Series Installation And Setup Manual page 189

Gx series;
Table of Contents

Advertisement

Ev
SIA Event
Log
Description
Event
K - Heat (Custom SIA - See Note 2)
KA
Alarm
Note 1
KB
Bypass
OMITTED
FORCEOMT+
KJ
Trouble Rest
LOW RES-
HIGH RES-
KR
Alarm Restore
Note 1
KT
Trouble
LOW RES+
HIGH RES+
KU
Unbypass
FORCE OMT-
L - Phone, Program
LB
Program begin
ENGINEER+
TEST O/P
FULL TEST
MOD T/D
MOD CODES
MOD REM
OMIT ZONE
ENG PARAM
ENG ZONES
ENG O/PS
ENG LINKS
ENG SOAK
ENG DIGI
ENG PRINT
ENG QUICK
ENG DIAG
ENG GROUP
ENG ASSEM
ENG TMRS
ENG CHECK
LR
Line Restore
LINE FAIL-
LINE FAIL-
LT
Line Trouble
LINE FAIL+
LINE FAIL+
LX
Local Prog end
ENGINEER-
M - Medical (Custom SIA - See note 2)
MA
Alarm
Note 1
MB
Bypass
OMITTED
FORCEOMT+
MJ
Trouble Rest
LOW RES-
HIGH RES-
MR
Alarm Restore
Note 1
MT
Trouble
LOW RES+
HIGH RES+
MU
Unbypass
FORCE OMT-
O - Opening
OA
Open Report
UNSET
OG
Open Area
UNSET
KSW UNSET
OK
Early Open
U/S EARLY
OP
Open Report
UNSET
KSW UNSET
OR
Disarm alarm
SYS RESET
PA RESET
TAMP RST
SYS RESET
PA RESET
TAMP RESET
LF RESET
GX-Series Control Panel Installation and Setup Guide
Log Event
Description
zone in alarm
zone omitted
Force omit after rearm
Restor zone resistance
Restor zone resistance
zone restored
Low resistance on zone
High resistance on zone
Unomitted after rearm
Engineer mode entered
Zone Tel line fail rest.
Module Tel line fail rest.
Zone Tel line fail trouble
Mod Tel line fail trouble
Engineer mode exited
zone in alarm
zone omitted
Force omit after rearm
Restor zone resistance
Restor zone resistance
zone restored
Low resistance on zone
High resistance on zone
Unomitted after rearm
Automatic Unset
Part Unset
Keyswitch part unset
Unset Early
Unset
Keyswitch unset
All Burglar alarms reset
All PA alarms reset
All Tamper alarms reset
Ksw reset Burglar alarm
Ksw reset PA alarms
Ksw reset Tamp alarm
B-5
Ev Type
Trigger
ZONE
5.CUS ZON
ZONE
8.OMIT
ZONE
8.OMIT
ZONE
15.TROUBL
ZONE
15.TROUBL
ZONE
5.CUS ZON
18.ZN RESTO
ZONE
15.TROUBL
ZONE
15.TROUBL
ZONE
8.OMIT
MISC
ALWAYS TR
USER
NONE
SET
NONE
USER
NONE
USER
NONE
USER
NONE
USER
NONE
USER
NONE
USER
NONE
USER
NONE
USER
NONE
USER
NONE
USER
NONE
USER
NONE
USER
NONE
USER
NONE
USER
NONE
USER
NONE
USER
NONE
USER
NONE
ZONE
12.MD/COM
MOD
12.MD/COM
ZONE
12.MD/COM
MOD
12.MD/COM
EVENT
ALWAYS TR
ZONE
5.CUS ZON
ZONE
8.OMIT
ZONE
8.OMIT
ZONE
15.TROUBL
ZONE
15.TROUBL
ZONE
5.CUS ZON
18.ZN RESTO
ZONE
15.TROUBL
ZONE
15.TROUBL
ZONE
8.OMIT
EVENT
10.SETTING
USER
10.SETTING
ZONE
10.SETTING
EVENT
10.SETTING
USER
10.SETTING
ZONE
10.SETTING
USER
11.RESET
USER
1.PA/DURE
USER
9.TAMPER
EVENT
11.RESET
EVENT
1.PA/DURE
EVENT
9.TAMPER
USER
20.FAULT
Contact
ID Event
Note 1
573
573
380
380
Note 1
380
380
573
627
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
351
351
351
351
627
Note 1
573
573
380
380
Note 1
380
380
573
401
401
409
451
401
409
313
465
313
313
465
313
313

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gx-520Gx-48