No
Event text
1
Default
2
AT/R Power
AC Trouble, AC Restoral
3
BA/R Burglary
Burglary Alarm, Burglary Restoral
4
DG/D Access
Access Granted, Access Denied
5
FA/R Fire
Fire Alarm, Fire Restoral
6
GA/R Gas
Gas Alarm, Gas Restoral
7
HA/R Holdup
Holdup Alarm, Holdup Restoral
8
KA/R Heat
Heat Alarm, Heat Restoral
9
LT/R Line Fail
Line Trouble, Line Restoral
10
MA/R Medical
Medical Alarm, Medical Restoral
11
PA/R Panic
Panic Alarm, Panic Restoral
12
QA/R Assist
Emergency Alarm, Emergency Restoral
13
RO/C Relay
Relay Open, Relay Closed
14
SA/R Sprinklr
Sprinkler Alarm, Sprinkler Restoral
15
TA/R Tamper
Tamper Alarm, Tamper Restoral
16
WA/R Water
Water Alarm, Water Restoral
17
YT/R Battery
Battery Alarm, Battery Restoral
18
ZA/R Freezer
Freezer Alarm, Freezer Restoral
NOTE: If two zones, programmed as Custom SIA, activate within the confirm time window, whether it be in the
SET (ARMED) or UNSET (DISARMED) condition, then a CONFIRM is logged.
8 = Activity Mon.
This attribute allows a zone to be checked for activity during a set (armed) time period or set/unset
(arm/disarm) cycles. The options are:
0 = None
1 = Type1
2 = Type2
3 = Type3
4 = Type4
5 = Type5
6 = Type6
The default option is 0 = None.
If the zone does not activate at least once within the programmed criteria a zone masked fault is indicated at
the panel. The fault is logged as a masked event which indicates that the zone has been inactive for the
programmed period. See Option 51.61=Parameters.Activity Monitoring.
9 = Res. Select
This option allows the zone resistor configuration to be selected from a pre-defined value.
00 = System (follows the system default as programmed in parameter 51.46 = Zone Resistance)
Option 01 = Preset 1 - 1k (double balanced)
Option 02 = Preset 1 - 1k (end-of-line)
Option 03 = Preset 2 – 2.2k (double balanced)
Option 04 = Preset 2 – 2.2k (end-of-line)
Option 05 = Preset 3 – 4.7k (double balanced)
Option 06 = Preset 3 – 4.7k (end-of-line)
Option 07 = Preset 4 – 5.6k (double balanced)
Option 08 = Preset 4 – 5.6k (end-of-line)
Option 09 = 1k Fault (double balanced)
Option 10 = 1k Fault (end-of-line)
The values assigned by each of the options are shown in tables 10 and 11, Parameter 51.46=Zone Resistance.
GX-Series Control Panel Installation and Setup Guide
Description
Alarm Closed
DG
MA
RO
WA
Table 6-14. Customizable Mnemonics
6-55
Omit
Unomit
AT
AR
BB
BU
BA
BR
BB
BU
DD
BB
BU
FA
FR
FB
FU
GA
GR
GB
GU
HA
HR
HB
HU
KA
KR
KB
KU
LT
LR
BB
BU
MR
MB
MU
PA
PR
PB
PU
QA
QR
QB
QU
RC
BB
BU
SA
SR
SB
SU
TA
TR
TB
TU
WR
WB
WU
YT
YR
BB
BU
ZA
ZR
ZB
ZU
Troub
Tr. Res
Test
Tamp
BT
BJ
BX
BT
BJ
BX
DT
DJ
BX
FT
FJ
FX
GT
GJ
GX
HT
HJ
BX
KT
KJ
BX
BT
BJ
BX
MT
MJ
BX
PT
PJ
BX
QT
QJ
BX
BT
BJ
BX
ST
SJ
BX
BT
BJ
TX
WT
WJ
BX
BT
BJ
BX
ZT
ZJ
BX
TA
TA
TA
TA
TA
TA
TA
TA
TA
TA
TA
TA
TA
TA
TA
TA
TA