GX-Series Control Panel Installation and Setup Guide
Fail to Set (Arm)
An output type (Option 53-Program output 40, Fail Set) is available that activates if a full set (arm) has
not occurred after a programmed period of time (determined by Option 51-Parameter 35, Fail to Set)
from the start of the setting (arming) procedure.
Power Failure While System is Set (Armed)
When power is restored to the system, following a complete mains (AC) and standby battery (DC) power
failure, the system attempts to return to the set (armed) status — full or part — prior to the power failure.
The system begins the setting (arming) procedure. If there are no zones open that prevent the system from
setting, at the end of the programmed exit time, the appropriate groups and parts are set.
6-9