GX-Series Control Panel Installation and Setup Guide
*
Source Type
Modifier
a) Not Used
-
b) Zone Address
Off
On
c) User Code
Off
On
d) Output Address
Off
On
e) Link Timer
Off
On
Example
Display
This link is not operational
*1014
When the zone is opened the link is active.
When the zone is closed the link is inactive.
*1014
When the zone opens first time, the link is activated.
When the zone opens a second time, the link is deactivated.
*001
When the code is entered, the link is activated momentarily only.
This option is only practical to trigger a destination event, for
example, an output pulse.
**001
When the code is entered first time, the link is activated.
When the code is entered the second the link is deactivated.
#1014
When the output is on, the link is active.
When the output is off, the link is inactive.
*#1014
When the output turns on first time, the link is activated.
When the output turns on second time, the link deactivates.
LT01
When the Link timer times out, the link activates momentarily only.
This option is only practical to trigger a destination event, for
example, an output pulse.
*LT01
When the Link timer times out, the link is activated.
When the Link timer times out a second time, the link is
deactivated.
Table 6-22. Link Source
6-80