GX-Series Control Panel Installation and Setup Guide
Omitted (Bypassed) Zones
If zones are omitted (bypassed) when the system starts setting, this is indicated on the keypad. The keypad
indicates how many zones are omitted.
Expiration Warning
During the last 25% of the programmed exit time outputs programmed as Entry/Exit Horn begin to pulse
rapidly, indicating that time is running short.
System Set (Armed) Indication
At the end of the exit time the Entry/Exit Horns become silent for four seconds. This allows the door to be
locked and secured and gives the detectors time to settle before the system finally sets. Two long tones are
emitted to confirm that the system has set. If all groups are set (armed) the keypad briefly displays the
message SYSTEM IS SET before returning to the normal banner.
Group Logic Setting (Arming) Restriction
If Setting Logic has been assigned to a group (refer to 63.1.2 = OPTIONS.Groups.Setting Logic), the set
(armed) status of the groups must satisfy the conditions defined in the option to permit the group to set. If
the Setting Logic conditions are not satisfied, then the group cannot set. If multiple groups are being set
simultaneously, but one group is restricted due to the programmed Setting Logic, the remainder of the
groups set. The restricted group does not set; there is no warning or indication given.
If the programmed Setting Logic results in none of the selected groups being allowed to set, a warning
message is displayed on the keypad. This message does not appear if at least one group sets.
Groups not set
[<],[>] to view
GX-069-V0
Entry Time
The system begins the unsetting (disarming) routine whenever a Final or Entry zone activates. The
Entry/Exit horns pulse slowly indicating that the entry time countdown has started. The user must go
directly to the keypad, using the agreed entry route, and unset (disarm) the system before the entry time
expires. When 75% of the entry time has elapsed the Entry/Exit horns pulse rapidly, indicating that time
is running short.
Timeout (Slow Entry)
If the entry time expires before a valid code is entered to unset (disarm) the group, a full alarm occurs. This
is recorded in the event log as a Timeout against the group which was in the process of being unset.
Straying from the Entry Route
If, during the entry routine, the user strays from the agreed entry route and activates a zone in a protected
area, a full alarm occurs.
Abort Time
Should the user exceed the entry time or stray from the entry route a full alarm occurs. However the
activation of the intruder output can be delayed to allow time for the user to abort the remote signaling. The
Abort Time parameter can also be programmed so that an Intruder alarm is activated immediately when
the entry time expires or a zone is activated, but entry of any valid code cancels the alarm and deactivates
the Intruder outputs without the need for a system reset.
Abort Setting (Arming) Message
Zones that are open or opened during the exit period are indicated to the user by a rapid audible tone from
the entry/exit horns. The keypad displays the open zones and then prompts the user to abort the setting
(arming) by pressing the esc key. This message is designed to prevent users from re-entering the building,
closing the open zones, allowing the system to set (arm) and trapping the user in the building.
6-8