Honeywell GX-Series Installation And Setup Manual page 168

Gx series;
Table of Contents

Advertisement

GX-Series Control Panel Installation and Setup Guide
6. Press the esc key three times to escape from the Timers option.
NOTE: The Timer Status can be switched On and Off by users via option 45 = TIMER CONTROL.
4 = Holiday Period
This is the holiday period programmed in 45.2.1. Timer Control.Holidays.Modify Dates. Up to 32
holiday periods can be viewed with this option.
5 = Holiday Schedule
This is an alternative schedule that is used if option 45.2. Timer Control.Holidays is activated. The
system defines a selection of holiday dates (65.1.4) and then a schedule of times can be used on those
dates under this option. Up to 67 holiday schedules can be selected.
6 = Pattern Day
The Pattern Day can only be allocated by the engineer. This option determines the programmed timers
that are effective when the Weekend Day option (45.6.1) is selected by the user; the timers of the
selected
Pattern Day are adopted by the days selected for weekend work.
On selecting this option the programmed Pattern Day is displayed; the default is 1 = MON. Use the A>
or <B keys to select the required day or days and press the ent key to accept the programming and
return to the previous menu level:
1 = MON
2 = TUE
3 = WED
4 = THU
5 = FRI
65.2 = Timer Outputs
Once the times have been programmed and the Status is set to 1=On, the Timer-A or Timer-B outputs
53.29 and 53.30 are activated at the On times and deactivated at the Off times programmed in
65.1=Weekly Schedule. User codes that they have been attributed to a Time Zone A or B are invalid
between an On time and the next Off time for the appropriate timer.
65.3 = Autoset
Each group can be programmed with up to 67 (dependent on panel variant) Autoset (armed) times over a 7
day period. These can be combined in any order of On and Off times as required. When the system has been
set (armed) by the Autoset (armed) function, outputs programmed as Autoset (armed) (refer to option 53
= PROGRAM OUTPUTS) are activated; the Set outputs are also activated.
Programming Autoset
If groups are enabled (refer to option 63 = OPTIONS) the keypads prompts for the group that the autoset
time is to be allocated to. Press the A> or <B keys to step through the groups until the required number is
displayed and press the ent key.
NOTE: The group can be directly selected by entering the group number. Larger GX-Series systems have 32
groups; these are displayed in blocks of eight groups, sub-divided into A, B, C and D:
W01 ON
ON
08:30
ON OFF
17:00
Group Block
Physical Groups
A1-8
1-8
B1-8
9-16
C1-8
17-24
D1-8
25-32
Table 6-30. Groups