NOTE: The programmed times cannot be modified using this option. All of the programmed timers - Weekly
Schedule, Timer Outputs, Autoset and Lockout - can be printed out using option 57.11 =
SYSTEM PRINT.Timers.
45.2 = Holidays
This function allows up to 32 holiday periods to be allocated. A Start and End date is entered for each
holiday period using the 1=Modify Dates option, and the groups that are affected by the programmed
holiday periods are assigned using the 2 = Assign Groups function. The operation of all timers for the
assigned groups is suspended during these dates; the last operation of the Timers before the start date
remains in operation until the first operation after the end date. For example, a code which has been
allocated the Timer A period in the CODES option (42.1.4.1) will be inoperative during the programmed
holiday period if the Timer A is in the On time when the holidays starts.
1 = Modify Dates
On selecting this option, the first holiday period with 1=Name and 2=Modify Dates options are
displayed. Upon selection of 2=Modify Dates, the Start and End dates for holiday period 1 are
displayed; an arrow (>) points to the Start date. If no dates have been entered for this period, then the
display shows * */* *. To program the Start date, press the ent key; the date display changes to
>DD/MM<; enter a valid four digit number and press the ent key to accept the selection; the year is not
required, only the day and months (dd/mm).
Press the # key to move to the end date and follow the procedure for programming the Start date. The #
key toggles between the Start and End dates for each holiday; the arrow (>) indicates which date is
currently selected.
To remove a programmed date, press the * key. The date display returns to * */* *.
Use the A> or <B key to move between the different holiday periods or enter the number of the holiday
period (1 – 10) to be programmed.
The holiday periods can only be programmed by the master manager and engineer. Users can access this
option, however, they can only view the programmed holiday dates.
2 = Assign Groups
This function determines which of the groups are affected by the programmed holiday periods.
On selecting the Assign Groups option, the groups currently assigned to the programmed holiday
periods are indicated by a Y below the group; an N is displayed below the unassigned groups. All groups
default to Y. Pressing the group number toggles the group status. When the required groups have been
assigned to the holidays, press the ent key to accept the programming and return to the previous menu
level.
Multi-group Systems
The larger GX-Series panels have 32 groups; these are displayed on the keypad in blocks of eight groups,
subdivided into A, B, C and D. Press the A> or <B key to display each of the group blocks.
Press keys 1 – 8 to assign the relevant groups in each block to the user.
45.3 = Early Open
If the Early Open option (45.3.2) is enabled, the Lockout OFF time (refer to option 65 = TIMERS) for the
following day is brought forward by the number of minutes (0 – 240) programmed in parameter 44 = Early
Open. This allows the system to be manually unset (disarmed) earlier than normal.
1 = Early Times
If the Timer is set to off, the operation of the Timer is suspended; this option cannot be used to alter the
programmed times. The timer defaults to 0 = Off. To switch the timer on, select change the setting to 1=On.
The Timer Status can also be altered through menu option 65.1 by the engineer only.
On selecting the option, the early opening status of the groups is displayed; early opening enabled is
indicated by a Y below the group; an N is displayed below the groups that are not programmed to open early.
All groups default to N.
GX-Series Control Panel Installation and Setup Guide
6-29