21 Line Fail (Reflex)
The Line Fail output is activated whenever a Line Fail zone is active or the telecom module detects and
sustains a line failure for more than 30 seconds.
22 Video (Pulse)
The Video output is activated by the Video zone when the system is set (armed). This output can be used to
activate video recorder or video transmission systems.
23 Comm Fail (Latch)
The Comm Fail output is activated whenever there is a communication failure on the telecoms module
telephone line. A fail to communicate event overrides the remaining Bell Delay period.
24 Batt Test
This output is activated when a battery load test is in progress. Refer to option 61.1.4 =
Diagnostics.Latest.PSU Comms.
25 Wrong CD
This output is activated whenever a wrong code alarm occurs. That is, when six wrong codes in succession
are entered at the keypad. The output, by default pulses on for 90 seconds.
26 Alert (Latch)
The Alert output is activated when the control panel loses communication with one of the remote modules or
keypads.
27 Fire Delay (Latch)
The Fire Delay output is activated whenever a Fire zone is activated. The activation of the output is
delayed subject to the period determined by the 03=Abort Time parameter. The Fire Delay output is not
subject to the Rearm parameter: it latches on and remains active until a valid code (type 2 or above) is
entered.
28 No Re-Arm (Latch)
The No Rearm output is activated on a full alarm event during the set (armed) state: it is subject to the
Bell Delay parameter. The No Rearm output is similar to the strobe output, but it stays on at the end of
the bell time, until unset (disarmed).
29 Timer A (Reflex)
The Timer-A output is controlled by the Timer-A option (refer to option 65=Timers A/B) and activates in
accordance with the programmed on and off times assigned to the function.
30 Timer B (Reflex)
The Timer-B output is controlled by the Timer-B option (refer to option 65=Timers A/B) and activates in
accordance with the programmed on and off times assigned to the function.
NOTE: If the TIMER A or B outputs are programmed as LATCH mode, then they can only be reset by a user
code with access to all of the groups assigned to the relevant timer.
31 Walk Test (Reflex)
The Walk Test output is activated when a zone included in the walk test is tested (refer to option 31=Walk
Test).
32 Zone Omit (Reflex)
The Zone Omit ouput is activated as soon as a zone is omitted from the system by option 11=OMIT
ZONES or by option 54=LINKS. If the Output Mode attribute is assigned as:
Reflex (default) the output remains active until the zone is reinstated;
Latch the output is reset on entry of a valid code.
33 Warning (Latch)
The Warning output is activated by the first occurrence of a high (1200-1300Ω) and low (800-900Ω) resistance
reading on each of the system zones in a single 24 hour period: the activating zone is recorded in the log.
NOTE: The time period finishes at midnight, not 24 hours from first activation.