Option 58 – Keypad
The keypads connected to the GX-Series control panel can be assigned individual attributes allowing each
keypad to respond in a particular way. On selecting the Keypad option the details of the first keypad
connected to the system are displayed.
The required keypad is selected by entering the keypad address or by using the A> and <B keys and then
pressing ent; the keypad displays 1=A-key. Press the A> and <B keys to select the required option and
press the ent key.
NOTE: Wen the address of the keypad currently being used is displayed, a black square flashes on and off over
the first digit of the keypad address.
1 = A-key
Code Status
This option assigns a menu function to the A key. On selecting the option the keypad displays 1 = Code
Status, this determines the method of operation of the A key:
0 = OFF [ ] - A key disabled
1 = WITH CODE [+] - A key requires code to be entered prior to operation
2 = NO CODE [–]— A key is a single touch operation no code is required
Select the required Code Status and press the ent key.
NOTE: he Code Status assigned to the key is displayed when selecting the keypad address, for
example A[12]– indicates that the A key does not require a user code.
Menu Option
To assign one of the menu options to the A key, press the A key to move to the 2 = Menu option and press
the ent key. The keypad displays the currently assigned menu option.
To assign a new menu function, enter the full menu option number 11 – 71 or press the A> and <B keys
until the required menu option is displayed; press the ent key to accept the selection and return to the
previous menu level.
2 = B-key
The programming of the B key is identical to that of the A key.
3 = Buzzer Mimic
This option determines whether the keypad buzzer mimics the function of the programmed keypad
output (refer to option 53 = PROGRAM OUTPUTS). The default function of the keypad output is
Entry/Exit Horn and the default Mimic defaults to On, therefore the keypad buzzer operates as an
Entry/Exit Horn at factory setting.
To disable the keypad buzzer from mimicking the output select 0 = Off.
4 = Backlighting
This option determines when the keypad backlighting switches on and off.
0 = always off,
1 = always on (default),
2 = on when the system is unset; off when the system is set; switches on when the keys are pressed,
KEYPAD ADDRESS
0 A[ 2] + B [ 3 ] -
FLASHING CURSOR
Mimic=
IF KEYPAD VIEWED
IS THIS KEYPAD
OPTION
0 A-key
2=Timed
6-106
OPTION
OPTION
1
2
Light=
OPTION
3
4
GX-077-V0