GX-Series Control Panel Installation and Setup Guide
Operating RSS Software on the Primary or Backup Computer
1. Open the Frontshell + Commserver program.
2. Enter a user name and password [defaults are manager and password, respectively].
3. Double click on the required account name, and the V6 application opens up.
4. Return to the Start Menu and open the Event Monitor.
The RSS package is defaulted to show 100 screen events. To view more than 100 events, open the Setup
Menu, and then System Parameters. Enter a password and then enter the desired value for "Screen
Events."
During RSS operation, if the computer stops receiving event messages and "line fail" appears, or the monitor
turns black and the computer resets, the secondary computer must be used.
To set up the backup computer:
1. Power on the backup computer.
2. Open the RSS software as described above.
3. Remove the Ethernet/PSTN line from the primary computer and plug it into the backup computer.
NOTES: The backup computer must have the same or greater system requirements as the primary computer.
The same revision RSS software must be used on both the primary and backup computers.
Performing a System "snapshot" on RSS Software
1. Follow steps 1 - 3 above for operating RSS software.
2. Open the Connect Menu in the V6 application.
3. Select Dial and enter a password or click OK.
4. Once connection is made, open the Communication Menu and open Online Keypad. Online Keypad will
refresh in about five seconds.
UL NOTES:
In UL approved systems the monitoring equipment must use a UL listed uninterruptible power supply (UPS).
To backup the monitoring computer, plug the computer's AC wire into the UPS.
For UL installations, PC monitoring stations and for UL294 installations Data processing equipment and office
appliance and business equipment used as central supervisory station equipment must meet the below
standards:
UL 114: Standard for Office Appliances and Business Equipment
and
UL 478: Standard for Information Processing and Business Equipment
or
UL 60950: Standard for Information Technology Equipment
UL Installation Requirements
U L
This system is required to be installed with applicable UL Installation Standards, such as UL827.
Commercial Burglary Requirements
The following requirements apply to all UL Commercial Burglary installations:
1. All groups must be owned and managed by the same person(s).
2. All groups must be part of one building at one street address.
3. The audible alarm device(s) must be placed where it/they can be heard by all groups.
4. The control cabinet must be protected from unauthorized access. This can be done by installing a tamper
switch on the cabinet door (supplied).