Honeywell GX-Series Installation And Setup Manual page 115

Gx series;
Table of Contents

Advertisement

Batt
Output Functions
Low
Zone Function
15
01
Final
02
Exit
03
Intruder
04
24 Hours
05
Security
06
Dual
07
Entry
08
Push Set
09
Keyswitch
10
Secure Final
11
Part Final
12
Part Entry
13
PA
14
PA Silent
15
PA Delay
16
PA Delay Silent
17
Link
18
Spare
19
Fire
20
Tamper
21
Bell Tamper
22
Beam Pair
23
Battery Low
24
Line Fail
25
AC Fail
26
Log
27
Remote Access
28
Video
29
Video Exit
30
Intruder Delay
31
Log Delay
32
Set Log
33
Custom-A
34
Custom-B
35
Exit Guard
36
Mask
37
Urgent
38
PA Unset
39
Keyswitch Reset
40
Bell Fail
41
Intr Low
42
Intr High
43
PSU Fault
44-46
Not Used
47
Vibration
48
ATM-1
49
ATM-2
50
ATM-3
51
ATM-4
52
Alarm Extend
Key:
S = Activates when system is set (armed)
P = Activates when system is Part set (Part armed)
U = Unset (disarmed)
A = Activated in any condition
- = No effect
? = Activation dependant on system programming
X = Activates during Exit Time
E = Activates during Entry
L = Switches output off if linked to destination output
T = Activates if zone resistance is less than value for tamper s/c or greater than value for tamper o/c
O = Activates when zone is omitted (bypassed)
E/E
Fire
Horn
Horn
Part Set Confirm
16
17
18
19
-
-
S
SXE
-
-
-
S
SXE
-
-
-
S
SXE
-
-
-
S
A
-
-
-
S
A
-
-
-
S
SXE
-
-
-
S
SXE
-
-
-
-
X
-
-
-
-
-
X
-
-
A
A
X
-
-
A
SXE
X
-
-
A
XE
X
-
-
A
-
-
-
-
A
-
-
-
-
-
-
-
-
-
A
A
-
?
?
?
?
?
-
-
-
-
-
-
A
A
A
-
-
-
A
A
-
-
-
A
A
-
-
-
S
SXE
-
U
-
-
-
-
-
-
-
U
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
S
SXE
-
-
-
S
SXE
-
-
-
S
SXE
-
-
-
-
-
-
-
-
-
-
-
?
?
?
?
?
?
?
?
?
?
L
L
L
L
L
-
-
S
SXE
-
-
-
A
A
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
S
SXE
-
-
-
S
SXE
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
A
A
-
A
T
Table 6-21. Output Activations per Zone
GX-Series Control Panel Installation and Setup Guide
Line
Comm
Fail
Video
Fail
20
21
22
23
-
-
S
-
S
-
S
-
S
-
S
-
-
-
S
-
-
-
S
-
S
-
S
-
-
-
S
-
-
-
-
-
-
-
-
-
S
-
S
-
S
-
S
-
S
-
S
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
?
?
?
?
-
-
-
-
-
-
V
-
-
-
S
-
-
-
S
-
-
-
S
-
-
-
-
-
-
A
-
-
-
-
-
-
-
-
-
-
-
-
-
-
S
-
S
-
S
-
S
-
-
-
S
-
-
-
-
-
-
-
-
-
?
?
?
?
?
?
?
?
L
L
L
L
-
-
S
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
S
-
S
-
S
-
S
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
6-69
Batt
Wrong
DLYD
Test
CD
Alert
Fire
24
25
26
27
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
S
-
-
-
S
-
-
-
S
-
-
-
A
-
-
-
A
-
-
-
-
-
-
A
?
?
?
?
-
-
-
-
-
-
A
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
?
?
?
?
?
?
?
?
L
L
L
L
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
A
No Re-
arm
28
-
S
-
S
-
S
-
S
-
S
-
S
-
S
-
-
-
-
-
-
-
-
-
-
-
-
?
-
-
A
-
S
-
S
-
S
-
-
-
-
-
-
-
-
-
-
-
S
-
S
-
S
-
-
-
-
?
?
L
-
S
-
A
-
-
-
-
-
-
-
S
-
S
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gx-520Gx-48

Table of Contents