Appendix B: SIA and Contact ID Event Codes
Ev
SIA Event
GX Log
Description
Event
A - Alarm Cause
AC
Alarm Cause
ALM CAUSE
A - AC Power
AR
AC Restoral
AC FAIL-
CU-AC-
AC FAIL-
STAND LOW-
CU FUSE-
AT
AC Trouble
AC FAIL+
CU-AC+
AC FAIL+
STAND LOW+
CU FUSE+
FUSE AUX1
FUSE AUX2
FUSE BELL
B - Burglary
BA
Burglary Alarm
ENTRY
EXIT+
INTRUDER+
24 HOURS+
SECURITY+
DUAL+
FINAL
SEC FINAL+
PRT FINAL+
PRT ENTRY+
BEAM PAIR+
VIDEO+
VIDEO EXT+
CUSTOM A+
CUSTOM B+
MASK+
INT DELAY
URGENT+
VIBRATION+
ATM-1+
ATM-2+
ATM-3+
ATM-4+
ALARM EXT+
T/O BURGL+
BB
Burg Bypass
OMITTED
FORCEOMT+
GRP OMIT+
OMIT VIBS
OMIT-ATM1+
OMIT-ATM2+
OMIT-ATM3+
OMIT-ATM4+
BC
Burg Cancel
KSW CANCL
CANCEL
BF
Intruder High
INTR HIGH
◊
The PC board uses a PTC device instead of a fuse. The PTC serves as an automatically resetting fuse.
GX-Series Control Panel Installation and Setup Guide
GX Log Event
Description
User report alarm cause
AC Fail zone restored
Control Unit AC restored
Module AC fail restored
Standby Battery Low
◊
Control Unit protection rest.
AC Fail zone trouble
Control Unit AC trouble
Module AC fail trouble
Standby Battery Low
◊
Control Unit protection trbl
◊
Aux1 protection trouble
◊
Aux2 protection trouble
◊
Bell protection trouble
Entry zone alarm
Exit zone alarm
Intruder zone alarm
24 hour zone alarm
Security zone alarm
Dual zone alarm
Final zone alarm
Secure final zone alarm
Part final zone alarm
Part entry zone alarm
Beam pair zone alarm
Video zone alarm
Video exit zone alarm
Custom A zone alarm
Custom B zone alarm
Mask zone alarm
Intruder Delay alarm
Urgent zone alarm
Vibration zone alarm
ATM-1 zone alarm
ATM-2 zone alarm
ATM-3 zone alarm
ATM-4 zone alarm
Extend zone alarm
Entry timeout with zone
Zone omitted
Force omit after rearm
Group omitted
Omit Vibration zone
Omit ATM-1 zone
Omit ATM-2 zone
Omit ATM-3 zone
Omit ATM-4 zone
Keyswitch Cancel
Cancel by user
Intruder zone alarm
B-1
Ev Type
GX
Trigger
USER
ALWAYS TR
ZONE
13.ELEC.ST
ZONE
13.ELEC.ST
MOD.
13.ELEC.ST
MOD
13.ELEC.ST
MISC
9.TAMPER
13. ELEC.ST
ZONE
13.ELEC.ST
ZONE
13.ELEC.ST
MOD.
13.ELEC.ST
MOD
13.ELEC ST
MISC
9. TAMPER
13.ELEC ST
MOD
9.TAMPER
13.ELEC ST
MOD
9.TAMPER
13.ELEC ST
MOD
9.TAMPER
13.ELEC ST
ZONE
NONE
ZONE
2.INTRUDE
ZONE
2.INTRUDE
ZONE
3.24 HOURS
ZONE
4.SECURITY
ZONE
2.INTRUDE
ZONE
NONE
ZONE
4.SECURITY
ZONE
2.INTRUDE
ZONE
2.INTRUDE
ZONE
2.INTRUDE
ZONE
2.INTRUDE
ZONE
2.INTRUDE
ZONE
5.CUS ZON
ZONE
5.CUS ZON
ZONE
4.SECURITY
ZONE
2.INTRUDE
ZONE
3.24 HOURS
ZONE
2.INTRUDE
ZONE
3.24 HOURS
ZONE
3.24 HOURS
ZONE
3.24 HOURS
ZONE
3.24 HOURS
ZONE
3.24 HOURS
ZONE
2.INTRUDE
ZONE
8.OMIT
ZONE
8.OMIT
USER
8.OMIT
EVENT
8.OMIT
EVENT
8.OMIT
EVENT
8.OMIT
EVENT
8.OMIT
EVENT
8.OMIT
ZONE
11.RESET
USER
11.RESET
ZONE
2. INTRUDE
Contact
ID Event
None
301
301
301
301
300
301
301
301
301
300
300
300
300
150
134
130
135
135
130
150
134
134
134
130
130
130
130
130
135
150
130
133
133
133
133
133
130
134
573
573
574
572
572
572
572
572
406
406
130