Honeywell GX-Series Installation And Setup Manual page 174

Gx series;
Table of Contents

Advertisement

GX-Series Control Panel Installation and Setup Guide
69.1 = Access Mode
The Access Control function can either be set to 0 = Disabled or 1 = Enabled. The default is Enabled. The
following pages describe the Door Control Module programming functions.
69.2 = NOT USED
69.3 = DCM
This option is used to program the GX-Series Door Control Module (DCM) access control readers. The DCM
can be fully integrated into the system, communicating on the AB lines and fully utilizing the facilities of the
GX-Series control panel. Each DCM can control up to two readers. The exit reader can be replaced with a
request to exit button.
When enabled, the options that are eligible for DCM programming are made available throughout the menu,
otherwise they do not appear, or appear as Option not Available.
Addressing the DCM
The DCM takes its address from a rotary hex switch on-board or by setting with DIP switches. Refer to
Section 5, Access Control, Door Control Module.
69.3.1 = DCM Parameters
This option defines the individual operational features of each of the Door Control Modules. On selecting this
option the address of the first DCM on the system is displayed along with the descriptor currently assigned
to it. If there are no DCM's on the system the message NO ENTRIES is displayed.
Select the required DCM address using the A> and <B keys pressing the ent key. The first parameter, 1 =
Descriptor is displayed. Use the A> or <B keys to move to the required parameter and press the ent key.
1 = Descriptor
This option is used to assign a name of up to 9 characters to each of the DCM's. This name is assembled
from the character set and/or library options. On selecting the Descriptor parameter the currently
assigned name is displayed on the top line - an underscore shows where the next character will be
positioned, and a selection of the alphabet is shown on the bottom line - the cursor flashes on the letter L.
Press the * key to erase the characters already assigned to the name.
The A> or <B keys can be used to move the alphabet left or right until the required character is
positioned underneath the flashing cursor. When the required character is in position press the ent key
to copy the character to the description in the top line. Repeat this procedure to assemble the required
Descriptor.
2 = Operation
This option determines how the DCM will operate. There are three choices;
0 = Entry and Exit
This option provides entry at one reader and exit at another reader.
1 = Entry and Entry
This option provides entry only at both readers
2 = Single entry
This option means that one reader is connected and its type is entry.
3 = System Group
This is the group that the DCM will report on for module tampers and diagnostics.
4 = Facility Code
This allows the cards to be programmed as a specific technology with a Facility code plus an ID.
1 = Code 1
2 = Code 2
3 = Code 3
4 = Code 4
5 = Reader (01 or 02)
This option allows the DCM readers to be set up with the 9 options that follow:
6-128

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gx-520Gx-48