If the address has previously been set and the address prompt does not appear, re-power the keypad and within
five seconds of power up, press the Console mode button then press the ent button to change the address.
2 - Register with the Control Panel
Once the address has been selected, the control panel must be repowered or, if another keypad is already
configured, exit from Engineer mode and the new TouchCenter will be registered. The Home Page will be
displayed and the keypad is ready to use.
NOTE: Refer to the control panel literature for valid addresses. One TouchCenter can be installed on each GX-
Series RS485 line.

Set-up Menu

The TouchCenter has a number of configuration settings which are set up directly within the keypad. To
access these settings, the TouchCenter must be in communication with the GX-Series Panel. The panel must
be in Engineer's mode. Proceed as follows:
1. From the home screen press the SECURITY button and then enter the Authorization code. This is the
Engineer PIN of the control panel. The Security screen is displayed.
2. Press the MORE CHOICES button to enter the More Choices screen.
3. Press the KEYPAD SETUP button to enter the Setup screen.
4. Press the KEYPAD TEST button. From this screen, the following options are available;
Self Diagnostics
A series of diagnostic tests are provided that allows verification of correct operation of the TouchCenter and
its connection to the GX-Series system. There are three diagnostic tests:
LCD Display Test
Audio Test
LED Test
Address
This allows the RS485 address to be changed. A change to this will require reconfiguration of the
TouchCenter with the control panel.

TouchCenter - Operation

For general operation refer to the on-screen information and to the separate user's guide. For programming
of the control panel, all options can be accessed via the virtual terminal mode, which emulates a standard
installer keypad. To access the terminal mode, press the terminal keypad icon in the lower left corner of the
Home Page.
NOTE: The TouchCenter memory card slot has not been investigated by UL.

Specifications

Mechanical
Dimensions:
Width: 7.17 in (182mm)
Height: 5.04 in (128mm)
Depth: 1.34 in (34mm)
Weight: 1.1 lb (500g) (approx)
Electrical
Operating Voltage: 12 VDC
Current Drain:
Backlight OFF, Sound ON: 120mA
Backlight ON, Sound OFF 150mA
Backlight ON, Sound ON: 170mA
Standby: 105mA