08 = Security
This option determines when and how a door can be locked and unlocked for access.
1 = Nightlock
This allows a time schedule to be allocated to determine when access to the door will be
blocked. Up to 67 weekly time schedules can be programmed. Setting the schedule to 00
disables the function.
2 = Unlock Time
This allows a time schedule to be allocated to determine when the door will be unlocked to
provide unrestricted access. Up to 67 weekly time schedules can be programmed. Setting the
schedule to 00 disables the function.
3 = Dual mode
This defines if access at a door requires dual authority or not via the assigned keypad. The
options are:
0 = Disabled
A card or a Pin is required to gain access.
1 = Card and Card
Two cards are required to gain access.
2 = Card and Pin
A card and a Pin from the same user are required to gain access.
4 = Dual Time
Option not available
09 = Menu Recall
This determines whether the user is allowed to apply the menu recall function at any DCM
reader. This is in addition to any DCM function that may be assigned. There are two options:
1 = Menu Function
Depending on the level of access granted in Option 68, Menu Access, the user can hold
their card at a compatible reader for three seconds to activate a single menu function
selected from the available list (11-71). A new option is assigned by pressing the A> or
<B keys until the required option is displayed or by entering the option number directly
and then pressing the ent key to accept the selection. Assigning a Double asterisk (**) to
the menu function makes it not used.
2 = Menu Mode
This determines how the menu function will operate. There are two options:
2 = Keypad assignment
This assigns a specific keypad address to work in conjunction with a MAX. This keypad
is used to display the menu action assigned in 1 = Menu Function.
69.3.2 = Card Format
This option selects what type of card is used with the DCM reader. There are five options:
0 = 26 bit
1 = Crp 1K 35 bit
2 = 37 bit no FC
3 = Northern 34 bit
4 = Custom.
1 = Format Name
This option is only available when 4 = Custom is selected as the format. It gives a name to the custom
format. The maximum number of characters in the name is 12.
2 = Card Length
The bit size of the card can be 26, 27, 32, 34, 35, 37 or 40.
NOTE: For UL294 installations use Northern 34 bit proximity cards.
1 = Triple Repeat
The card is presented to the reader three times to activate the menu.
2 = Recall Button
The recall button is pressed once to activate the menu.