Connecting power cords to the mains
V
CAUTION!
The power supply automatically adjusts to any mains voltage in the
range of 100 VAC to 240 VAC. You may only operate the server if its
rated voltage range corresponds to the local mains voltage.
Figure 12: Securing power cord
Ê Connect the power connector (1) to the power supply unit.
Ê Close the cable clamp around the power cord (2) and lock the cable
clamp (3) to secure the power cord.
Ê Connect the mains plug to a grounded mains outlet in the in-house power
supply network or a power outlet of the rack socket strip (see also
"PRIMECENTER Rack System" assembly guide).
I
To provide true phase redundancy, the second power supply should
be connected to a different AC power source from the other supply. If
one AC power source should fail, the server will still continue to run.
I
It takes about 60 seconds until power-on becomes possible.
RX2520 M1
Upgrade and Maintenance Manual
Basic hardware procedures
65