Concluding Steps; Removing 3.5-Inch Hdd Modules; Preliminary Steps - Fujitsu PRIMERGY RX2520 M1 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY RX2520 M1:
Table of Contents

Advertisement

Hard disk drives / solid state drives
Ê Insert the HDD module into a drive bay and carefully push back as far as it
will go (1).
Ê Fold back the lever to lock the HDD module in place (2).
7.3.2.4

Concluding steps

"Performing a RAID array rebuild" on page 94
Ê
7.3.3

Removing 3.5-inch HDD modules

Customer Replaceable Unit
(CRU)
Tools: tool-less
7.3.3.1

Preliminary steps

Ê If the HDD module to be removed is combined into a RAID array, please
proceed as follows:
RAID level
RAID 0
RAID 1
RAID 5
138
Procedure
Only remove an HDD module combined in a RAID 0
array if defective.
V
CAUTION!
Removing an operational HDD module will
result in data loss!
Removing an HDD module from a RAID 1 or RAID 5
array will not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or larger
capacity.
I
After replacing the HDD module, RAID rebuild
will be performed as a background process as
described in section
rebuild" on page
Upgrade and Maintenance Manual
Hardware: 5 minutes
"Performing a RAID array
94.
RX2520 M1