Appendix
Component
System board
CPU with CPU heat sink
1 memory module
Front panel module
Power supply unit
Table 12: Minimum startup configuration - components
Cable
Front panel cable
Power cable
Table 13: Minimum startup configuration - cables
"Shutting down the server" on page 51
Ê
"Disconnecting power cords" on page 52
Ê
Ê Take the system down to its minimum startup configuration.
"Connecting the server to the power source" on page 64
Ê
Ê Connect a keyboard, mouse and display to the server.
"Switching on the server" on page 66
Ê
V
CAUTION!
Since the fan module is not included in the minimum startup
configuration, the server must be shut down immediately after the
diagnostic process is complete (POST phase has been passed).
The minimum startup configuration must be used exclusively for
diagnostic purposes by maintenance personnel, never in daily
operation!
432
Notes
no TPM, UFM or expansion cards installed
installed in DIMM slot 1A
Notes
Upgrade and Maintenance Manual
RX2520 M1