V
CAUTION!
Only remove an HDD / SSD module during operation if the drive is
●
not currently being accessed. Observe the indicators on the HDD
module, as described in the operating manual of your server.
Under no circumstances should you remove an HDD / SSD module
●
while the system is in operation if you are not sure that the drive is
operated by a RAID controller and belongs to a disk array that is
operating in RAID level 0, 1, 1E, 10, 5, 50, 6 or 60.
An HDD / SSD module can only be replaced during operation in
conjunction with a corresponding RAID configuration.
All HDD / SSD modules (drives) must be uniquely identified so that
●
they can be reinstalled in their original mounting locations later. If this
is not done, existing data can be lost.
7.3.4.1
Preliminary steps
"Locating the defective server" on page 49
Ê
Ê Locate the defective HDD module as described in section
indicators on the front" on page
Only applicable for removing intact HDD modules:
Ê Before removing a non-defective HDD module, put the drive into "Offline"
mode using your RAID configuration software.
I
For further information, please refer to the "ServerView Suite RAID
Management" user guide and manuals of RAID controller.
7.3.4.2
Removing a 3.5-inch HDD module
"Removing a 3.5-inch HDD module" on page 139
Ê
7.3.4.3
Installing a 3.5-inch HDD module
"Installing 3.5-inch HDD modules" on page 136
Ê
7.3.4.4
Concluding steps
"Performing a RAID array rebuild" on page 94
Ê
RX2520 M1
51.
Upgrade and Maintenance Manual
Hard disk drives / solid state drives
"Local diagnostic
141