Hard disk drives / solid state drives
Ê Insert the HDD module into a drive bay and carefully push back as far as it
will go (1).
Ê Close the locking lever to lock the hard disk drive in place (2).
7.2.2.4
Concluding steps
"Performing a RAID array rebuild" on page 94
Ê
7.2.3
Removing 2.5-inch HDD / SSD modules
Customer Replaceable Unit
(CRU)
Tools: tool-less
7.2.3.1
Preliminary steps
Ê If the HDD / SSD module to be removed is combined into a RAID array,
please proceed as follows:
RAID level
RAID 0
RAID 1
RAID 5
In order to permanently remove an operational HDD module that is part of a
RAID array from the server, you first need to delete the array using
ServerView RAID Manager or BIOS Utility.
130
Procedure
Only remove an HDD module combined in a RAID 0 array if
defective.
V
CAUTION!
Removing an operational HDD module will result
in data loss!
Removing an HDD module from a RAID 1 or RAID 5 array
will not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or larger
capacity.
Upgrade and Maintenance Manual
Hardware: 5 minutes
RX2520 M1