Preliminary Steps; Removing The Odd - Fujitsu PRIMERGY RX2520 M1 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY RX2520 M1:
Table of Contents

Advertisement

Accessible drives
Tools: Torx Plus 6 screw driver

12.5.2.1 Preliminary steps

Ê Ask the system administrator to eject all remaining backup or optical media
from the backup or optical disk drive before removing it from the server.
"Disabling or suspending BitLocker functionality" on page 67
Ê
"Shutting down the server" on page 51
Ê
"Disconnecting power cords" on page 52
Ê
"Getting access to the component" on page 53
Ê
"Removing the fan box" on page 168
Ê

12.5.2.2 Removing the ODD

Figure 158: Removing the ODD (A)
Ê Disconnect the SATA cable (1) and the power cable (2).
Ê Pull the locking latch upward to unlock the ODD.
Ê Push the ODD out of the bay.